(E) Environment setting parameters
255
5
GROUP
E
???????
Parameters referred to
Pr.77 Parameter write selection
Pr.160 User group read selection
Pr.550 NET mode operation command source selection
Pr.551 PU mode operation command source selection
5.7.11
Free parameter
NOTE
•
Pr.888 and Pr.889
do not influence the operation of the inverter.
5.7.12
Setting multiple parameters as a batch
The read value is always "9999".
Any number within the setting range of 0 to 9999 can be input.
For example, these numbers can be used:
• As a unit number when multiple units are used.
• As a pattern number for each operation application when multiple units are used.
• As the year and month of introduction or inspection.
Pr.
Name
Initial value
Setting range
Description
888
E420
Free parameter 1
9999
0 to 9999
Any value can be input. The settings are
retained even if the inverter power is
turned OFF.
889
E421
Free parameter 2
9999
0 to 9999
Parameter settings are changed as a batch. Those include communication parameter settings for the Mitsubishi
Electric human machine interface (GOT) connection and the parameter setting for the rated frequency settings of 50
Hz/60 Hz and acceleration/deceleration time.
Pr.
Name
Initial value
Setting range
Description
999
E431
Automatic parameter setting
9999
1
Standard PID display setting
2
Extended PID display setting
10
GOT initial setting
(PU connector)
"Controller Type" in GOT:
FREQROL 500/700/800,
SENSORLESS SERVO
11
GOT initial setting
(RS485 terminals)
12
GOT initial setting
(PU connector)
"Controller Type" in GOT:
FREQROL 800 (Automatic
Negotiation)
13
GOT initial setting
(RS-485 terminal)
20
50 Hz rated frequency
21
60 Hz rated frequency
9999
No action