(E) Environment setting parameters
248
5.7.5
PU contrast adjustment
The above parameter is displayed as a simple mode parameter only when the LCD operation panel (FR-LU08) and the parameter unit (FR-
PU07) is connected.
5.7.6
Extended direct setting
• The monitor display can be switched from the Main monitor screen to the set point setting screen for the PID action by
simply
operation, according to the setting of
Pr.1000 Direct setting selection
. On each setting screen, turn
to
input a setting value, and press
to confirm the setting.
When
Pr.1000
="0"
When
Pr.1000
="1"
When
Pr.1000
="2"
Not displayed when PID control is disabled (
Pr.128
="0").
Indication of [NEXT] is not displayed when
Pr.1000
="0".
• To switch back the monitor display from the Extended direct screen or the Frequency setting screen to the Main monitor
screen, press
.
NOTE
• For the availability of the extended direct setting for your operation panel, refer to your FR-LU08 Instruction Manual.
???????
Parameters referred to
Pr.128 PID action selection
Contrast adjustment of the LCD of the LCD operation panel (FR-LU08) and the parameter unit (FR-PU07) can be
performed.
Decreasing the setting value lowers the contrast.
Pr.
Name
Initial value
Setting range
Description
991
E105
PU contrast adjustment
58
0 to 63
0: Low
63: High
The PID action set point setting screen can be displayed quickly on the monitor.
Pr.
Name
Initial value
Setting range
Description
1000
E108
Direct setting selection
0
0
Displays the Frequency setting screen.
1
Displays the Extended direct (set point
setting) screen.
2
Displays the Extended direct (set point
setting) screen and the Frequency setting
screen.
(SET)
One of the Main monitor screen
Example of screen switching and shifting when the PID control is enabled (
Pr.128
≠
"0")
Extended direct #1 screen
∗4
Extended direct #2 screen
∗4
Frequency setting screen
∗5
(NEXT)
(NEXT)
(NEXT)
∗3
(NEXT)
∗2
∗1
∗2,∗3
∗2,∗3
∗3
PREV
SET
NEXT
STOP
PU
Hz
Output frequency
1 2 : 3 4
0.00
N E X T
BACK
SET
NEXT
STOP
PU
Frequency Setting
Pres value
Set value
0.00Hz
100.00Hz
10.0PSI
10.0PSI
N E X T
BACK
SET
NEXT
STOP
PU
PID act set pnt
Pres value
Set value
10.0PSI
10.0PSI
N E X T
BACK
SET
NEXT
STOP
PU
2ndPID set point
Pres value
Set value
(BACK)