Parameter List
Parameter list (by parameter number)
116
Cal
ib
rat
io
n par
amet
e
rs
919
T110
Terminal 1 bias command (torque)
0 to 400%
0.1%
0%
919
T111
Terminal 1 bias (torque)
0 to 300%
0.1%
0%
920
T112
Terminal 1 gain command (torque)
0 to 400%
0.1%
150%
920
T113
Terminal 1 gain (torque)
0 to 300%
0.1%
100%
932
T410
Terminal 4 bias command (torque)
0 to 400%
0.1%
0%
932
T411
Terminal 4 bias (torque)
0 to 300%
0.1%
20%
933
T412
Terminal 4 gain command (torque)
0 to 400%
0.1%
150%
933
T413
Terminal 4 gain (torque)
0 to 300%
0.1%
100%
934
A630
PID display bias coefficient
0 to 500, 9999
0.01
9999
934
A631
PID display bias analog value
0 to 300%
0.1%
20%
935
A632
PID display gain coefficient
0 to 500, 9999
0.01
9999
935
A633
PID display gain analog value
0 to 300%
0.1%
100%
─
989
E490
Parameter copy alarm release
10
1
PU
990
E104
PU buzzer control
0, 1
1
1
991
E105
PU contrast adjustment
0 to 63
1
58
─
992
M104
Parameter for manufacturer setting. Do not set.
Dr
o
o
p
control
994
G403
Droop break point gain
0.1 to 100%, 9999
0.1%
9999
995
G404
Droop break point torque
0.1 to 100%
0.1%
100%
─
997
H103
Fault initiation
0 to 255, 9999
1
9999
─
998
E430
PM parameter initialization
0, 3003, 3103, 8009,
8109, 9009, 9109
1
0
─
999
E431
Automatic parameter setting
1, 2, 10, 11, 12, 13,
20, 21, 9999
1
9999
─
1000
E108
Direct setting selection
0 to 2
1
0
─
1002
C150
Lq tuning target current adjustment
coefficient
50 to 150%, 9999
0.1%
9999
Additional
fu
nct
ion
1003
G601
Notch filter frequency
0, 8 to 1250 Hz
1 Hz
0
1004
G602
Notch filter depth
0 to 3
1
0
1005
G603
Notch filter width
0 to 3
1
0
Cl
oc
k
fu
ncti
on
1006
E020
Clock (year)
2000 to 2099
1
2000
1007
E021
Clock (month, day)
1/1 to 12/31
1
101
1008
E022
Clock (hour, minute)
0:00 to 23:59
1
0
─
1015
A607
Integral stop selection at limited
frequency
0 to 2, 10 to 12
1
0
─
1016
H021
PTC thermistor protection
detection time
0 to 60 s
1 s
0
─
1018
M045
Monitor with sign selection
0, 1, 9999
1
9999
Tr
ace function
1020
A900
Trace operation selection
0 to 4
1
0
1021
A901
Trace mode selection
0 to 2
1
0
1022
A902
Sampling cycle
0 to 9
1
2
1023
A903
Number of analog channels
1 to 8
1
4
1024
A904
Sampling auto start
0, 1
1
0
1025
A905
Trigger mode selection
0 to 4
1
0
1026
A906
Number of sampling before trigger
0 to 100%
1%
90%
Functio
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
settin
g
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Содержание 800 Series
Страница 11: ...MEMO 10 ...
Страница 17: ...MEMO 16 ...
Страница 95: ...MEMO 94 ...
Страница 671: ...MEMO 670 ...
Страница 681: ...MEMO 680 ...