(G) Control parameters
602
Magnetic flux decay output shutoff and magnetic flux decay output
shutoff signal (X74 signal, Pr.850 = "2")
• The failure of inverter or increased error in motor may occur due to effect of the motor residual magnetic flux at the time
when the inverter output is shut off when frequent start and stop (inching operation) is repeated at the time of Real
sensorless vector control. If this is the case, set
Pr.850
= "2" (magnetic flux decay output shutoff) or turn ON the magnetic
flux decay output shutoff (X74) signal to decay the magnetic flux at a stop, and then shut off the output.
• With
Pr.850
= "2", deceleration starts at turning OFF of the start command, and the magnetic flux decay output shutoff is
activated when the estimated speed becomes lower than
Pr.10 DC injection brake operation frequency
.
• With the brake sequence function is set enabled, the magnetic flux decay output shutoff is activated when the frequency
becomes lower than 0.5 Hz or the
Pr.13 Starting frequency
setting, whichever smaller, during deceleration.
• Inverter output voltage shutoff timing when
Pr.850
= "2"
Maximum time for the magnetic flux decay operation
• Regardless of the
Pr.850
setting, the magnetic flux decay output shutoff will operate immediately when the Magnetic flux
decay output shutoff signal (X74) is turned ON. For the X74 signal, set "74" in any of
Pr.178 to Pr.189 (Input terminal
function selection)
to assign the function.
• Inverter output shutoff timing with X74 signal
Maximum time for the magnetic flux decay operation
• Since the torque will decrease at the time of magnetic flux decay output shutoff, set up so the mechanical brake will
operate.
• Magnetic flux decay output shutoff will be canceled at the time of restart and when the Pre-excitation/servo ON (LX) signal/
External DC injection brake operation start (X13) signal is turned ON.
RY2
ON
RUN
ON
ON
ON
ON
ON
Start command
(STF, STR)
Pr. 10 DC injection
brake operation
frequency
Mechanical brake
MC on the output side
Output voltage
Speed command
(rotation per
second)
Magnetic flux decay
processing time
∗
Magnetic flux decaying
Do not turn OFF MC
during this period
Normal operation
RY2
ON
RUN
ON
ON
ON
ON
ON
Start command
(STF, STR)
Mechanical brake
MC on the output side
Output voltage
Speed command
(rotation per
minute)
Magnetic flux
decay
processing time*
Magnetic flux decaying
Do not turn OFF MC
during this period
Pr. 13 Starting
frequency
or 0.5Hz
(whichever is lower)
During brake sequence
X74
Output voltage
RUN
Magnetic flux decay
processing time
∗
Do not turn off MC
during this processing time
ON
ON
ON
ON
Mechanical brake
MC on the output side
Mechanical brake
MC on the output side
ON
ON
X74 signal
MRS
Output voltage
RUN
ON
ON
ON
ON
MRS signal