Speed control under Real sensorless vector control, vector control, PM sensorless vector
control
158
• Functions of terminals 1 and 4 by control (
―
: no function)
When
Pr.868
≠
"0", the other functions of terminal 1 (auxiliary input, override function, PID control) do not operate.
When
Pr.858
≠
"0", PID control and speed commands using terminal 4 do not operate even when the AU signal is ON.
When both
Pr.858
and
Pr.868
are "1" (magnetic flux command) or "4" (torque limit), the function of terminal 1 has higher priority, and terminal 4
does not function.
Valid when vector control compatible options are installed and vector control is selected.
Pr.858 setting
value
Terminal 4 function
Pr.868 setting
Terminal 1 function
0
(Initial value)
Speed command (AU signal-ON)
0
(Initial value)
Speed setting auxiliary
Magnetic flux command
2
―
3
―
4
Torque limit (
Pr.810
= 1)
5
―
6
Torque bias (
Pr.840
=1 to 3)
9999
―
Magnetic flux command
0
(Initial value)
Speed setting auxiliary
―
Magnetic flux command
Magnetic flux command
2
―
3
―
4
Torque limit (
Pr.810
= 1)
5
―
6
Torque bias (
Pr.840
=1 to 3)
9999
―
4
Torque limit (
Pr.810
= 1)
0
(Initial value)
Speed setting auxiliary
Magnetic flux command
Power driving torque limit (
Pr.810
= 1)
2
Regenerative driving torque limit (
Pr.810
= 1)
Torque limit (
Pr.810
= 1)
3
―
―
4
Torque limit (
Pr.810
= 1)
Torque limit (
Pr.810
= 1)
5
―
6
Torque bias (
Pr.840
= 1 to 3)
9999
―
9999
―
―
―