Parameter List
Parameter list (by parameter number)
120
S
imp
le
p
o
sit
ion
co
nt
ro
l
1285
B183
Home position shift amount lower 4
digits
0 to 9999
1
0
1286
B184
Home position shift amount upper 4
digits
0 to 9999
1
0
1287
B185
Travel distance after proximity dog
ON lower 4 digits
0 to 9999
1
2048
1288
B186
Travel distance after proximity dog
ON upper 4 digits
0 to 9999
1
0
1289
B187
Home position return stopper
torque
0 to 200%
0.1%
40%
1290
B188
Home position return stopper
waiting time
0 to 10 s
0.1 s
0.5 s
1292
B190
Position control terminal input
selection
0, 1
1
0
1293
B191
Roll feeding mode selection
0, 1
1
0
1294
B192
Position detection lower 4 digits
0 to 9999
1
0
1295
B193
Position detection upper 4 digits
0 to 9999
1
0
1296
B194
Position detection selection
0 to 2
1
0
1297
B195
Position detection hysteresis width
0 to 32767
1
0
─
1298
B013
Second position control gain
0 to 150 s
-1
1 s
-1
25 s
-1
─
1299
G108
Second pre-excitation selection
0, 1
1
0
─
1300
to
1343
N500
to
N543
Communication option parameters.
For details, refer to the Instruction Manual of the option.
─
1348
G263
P/PI control switchover frequency
0 to 400 Hz
0.01 Hz
0 Hz
─
1349
G264
Emergency stop operation
selection
0, 1, 10, 11
1
0
─
1350
to
1359
N550
to
N559
Communication option parameters.
For details, refer to the Instruction Manual of the option.
─
1410
A170
Starting times lower 4 digits
0 to 9999
1
0
─
1411
A171
Starting times upper 4 digits
0 to 9999
1
0
─
1412
C135
Motor induced voltage constant
(phi f) exponent
0 to 2, 9999
1
9999
─
1413
C235
Second motor induced voltage
constant (phi f) exponent
0 to 2, 9999
1
9999
Lo
ad
ch
aracteri
st
ics faul
t d
e
tecti
o
n
1480
H520
Load characteristics measurement
mode
0, 1 (2 to 5, 81 to 85)
1
0
1481
H521
Load characteristics load reference
1
0 to 400%, 8888,
9999
0.1%
9999
1482
H522
Load characteristics load reference
2
0 to 400%, 8888,
9999
0.1%
9999
1483
H523
Load characteristics load reference
3
0 to 400%, 8888,
9999
0.1%
9999
1484
H524
Load characteristics load reference
4
0 to 400%, 8888,
9999
0.1%
9999
1485
H525
Load characteristics load reference
5
0 to 400%, 8888,
9999
0.1%
9999
1486
H526
Load characteristics maximum
frequency
0 to 590 Hz
0.01 Hz
60 Hz
1487
H527
Load characteristics minimum
frequency
0 to 590 Hz
0.01 Hz
6 Hz
1488
H531
Upper limit warning detection width
0 to 400%, 9999
0.1%
20%
1489
H532
Lower limit warning detection width
0 to 400%, 9999
0.1%
20%
1490
H533
Upper limit fault detection width
0 to 400%, 9999
0.1%
9999
1491
H534
Lower limit fault detection width
0 to 400%, 9999
0.1%
9999
1492
H535
Load status detection signal delay
time / load reference measurement
waiting time
0 to 60 s
0.1 s
1 s
─
1499
E415
Parameter for manufacturer setting. Do not set.
Functio
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
settin
g