(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
279
5
GROUP
F
5.8.3
Remote setting function
Remote setting function
• When
Pr.59
≠
"0" (remote setting enabled), the functions of the signals are as shown in the following table.
Even if the operation panel is located away from the enclosure, contact signals can be used to perform continuous
variable-speed operation, without using analog signals.
Pr.
Name
Initial
value
Setting
range
Description
RH, RM, RL
signal function
Frequency
setting
storage function
Deceleration to
the frequency
lower than the set
frequency
59
F101
Restart cushion time
0
0
Multi-speed setting
-
Disabled
1
Remote setting
With
2
Remote setting
Without
3
Remote setting
Without
(Turning STF/STR
OFF clears remotely-
set frequency.)
11
Remote setting
With
Enabled
12
Remote setting
Without
13
Remote setting
Without
(Turning STF/STR
OFF clears remotely-
set frequency.)
Signal name
Function
Description
STF/STR
Forward/Reverse
The inverter accelerates the motor in the forward or reverse direction up to
the main speed or to the frequency stored by the remote setting function.
RH
Acceleration
The set frequency increases according to the
Pr.44
setting.
RM
Deceleration
The set frequency decreases according to the
Pr.45
setting.
RL
Clear
The set frequency is cleared and the main speed is applied.
Terminal 2 (analog signal)
Main speed
The setting of the main speed is used as a base. The main speed is
increased by the RH signal and decreased by the RM signal.
Acceleration
Deceleration
Clear
Inverter
STF
RH
RM
10
2
5
RL
Connection
diagram for remote setting
Forward
rotation
SD
Time
Terminal 2
(main speed)
RM (Deceleration)
RL (Clear)
RH (Acceleration)
STF (Forward)
Cleared by RL
Decreased according to
the
Pr.45
setting
Increased
according to the
Pr.44
setting
ON
ON
ON
ON
Set frequency
(Hz)