(D) Operation command and frequency command
315
5
GROUP
D
Multi-speed setting for 4th speed or more (Pr.24 to Pr.27, Pr.232 to
Pr.239)
• The frequency from 4th speed to 15th speed can be set by the combination of the RH, RM, RL, and REX signals. Set the
running frequencies in
Pr.24 to Pr.27, Pr.232 to Pr.239
. (In the initial status, 4th to 15th speeds are invalid.)
• For the terminal used for REX signal input, set "8" in any of
Pr.178 to Pr.189 (Input terminal function selection)
to assign
the function.
When RH, RM and RL is set to OFF and REX is set to ON when "9999" is set to
Pr.232 Multi-speed setting (speed 8)
, the inverter runs by the
frequency set to
Pr.6
.
Input compensation of multi-speed setting (Pr.28)
• Speed (frequency) compensation can be applied for the multi-speed setting and the remote setting by inputting the
frequency setting compensation signal (terminals 1, 2).
NOTE
• The priority of the frequency commands by the external signals are "Jog operation > multi-speed operation > terminal 4
analog input > pulse train input > terminal 2 analog input". (For details on frequency commands by analog input, refer to
• Valid in the External operation mode or PU/External combined operation mode (
Pr.79
= "3" or "4"
.
• Multi-speed parameters can also be set during PU operation or External operation.
• The
Pr.24 to Pr.27
and
Pr.232 to Pr.239
settings have no priority among them.
• When
Pr.59 Remote function selection
≠
"0", the multi-speed setting is invalid since the RH, RM, and RL signals are for
remote setting.
• When performing analog input compensation, set
Pr.28 Multi-speed input compensation selection
to "1".
• Select the terminals (terminals 1, 2) to use for compensation input voltage (0 to ± 5 V, 0 to ± 10 V) at
Pr.73 Analog input
selection
.
• When using terminal 1 for compensation input, set
Pr.868 Terminal 1 function assignment
"0" (initial value).
• Changing the terminal assignment using
Pr.178 to Pr.189 (Input terminal function selection)
may affect the other
functions. Set parameters after confirming the function of each terminal.
???????
Parameters referred to
Pr.15 Jog frequency
Pr.59 Remote function selection
Pr.73 Analog input selection
Pr.79 Operation mode selection
Pr.178 to Pr.189 (Input terminal function selection)
Pr.868 Terminal 1 function assignment
10
2
5
Forward
rotation
Multi-speed selection
Frequency setting
potentiometer
Inverter
STF
REX
RH
RM
RL
SD
Time
Speed 8
Output frequency
(Hz)
∗1
Speed 9
Speed 10
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
Speed 4
Speed 5
Speed 6
Speed 7
ON
ON
ON ON ON ON ON ON
ON
ON
ON
ON
ON ON
ON ON
ON ON ON ON
RH
RM
RL
REX
ON ON ON
ON
ON
ON
ON
ON