(D) Operation command and frequency command
312
5.9.6
JOG operation
Note that these parameters are categorized as a simple mode parameter when the LCD operation panel or the parameter unit
is used. Setting of this parameter is enabled when the operation panel is connected and "0" is set to
Pr.160 User group read
selection
. (Refer to
.)
The
Pr.20
initial value is set to 60 Hz.
JOG operation using the external signals
• Operation can be started and stopped by the start signals (STF and STR signals) when the Jog operation selection (JOG)
signal is ON. (For the operation method, refer to
• While the JOGF or JOGR signal is input, Jog frequency setting (
Pr.15
) is used for operation. The rotation is forward while
the JOGF signal is input, and the rotation is reverse while the JOGR signal is input. (Direct JOG function)
• Use the JOG acceleration/deceleration time function (
Pr.16
) to set the acceleration/deceleration time for JOG operation.
• To use each signal, set the corresponding number selected from the following table in any of
Pr.178 to Pr.189 (Input
terminal function selection)
to assign the function to an input terminal.
The frequency and acceleration/deceleration time for JOG operation can be set. JOG operation is possible in both
External operation and PU.
JOG operation can be used for conveyor positioning, test run, etc.
Pr.
Name
Initial value
Setting range
Description
15
D200
Jog frequency
5 Hz
0 to 590 Hz
Sets the frequency during JOG operation.
16
F002
Jog acceleration/
deceleration time
0.5 s
0 to 3600 s
Sets motor acceleration/deceleration time during JOG
operation. For the acceleration/deceleration time, set the time
until the frequency
set in
Pr.20 Acceleration/deceleration
reference frequency
is reached.
The acceleration/deceleration times cannot be set separately.
Input signal
Pr.178 to Pr.189 settings
JOG
5 (
Pr.185
initial value)
JOGF
57
JOGR
58
Output frequency (Hz)
Pr.20
Pr.15
setting range
Pr.16
Forward
rotation
Reverse
rotation
Time
ON
ON
ON
JOG signal
Forward rotation STF
Reverse rotation STR
ON
ON
JOGF signal
JOGR signal
Time
Output frequency (Hz)
Pr.20
Pr.15
setting range
Pr.16
Forward
rotation
Reverse
rotation