(D) Operation command and frequency command
305
5
GROUP
D
Selection of control source in Network operation mode (Pr.338, Pr.339)
• There are two control sources: the start command source, which controls the signals related to the inverter stand command
and function selection, and the speed command source, which controls signals related to frequency setting.
• The table below shows the commands from the external terminals and communication (RS-485 terminals or
communication option) in the Network operation mode.
Operation
location
selection
Pr.338 Communication operation
command source
0: NET
1: EXT
REMARKS
Pr.339 Communication speed
command source
0:
NET
1:
EXT
2:
EXT
0:
NET
1:
EXT
2:
EXT
Fixed
function
(terminal-
equivalent
function)
Frequency setting through
communication
NET
―
NET
NET
―
NET
Terminal 2
―
EXT
―
―
―
―
Terminal 4
―
EXT
―
EXT
Terminal 1
Compensation
Selectab
le fu
nctio
n
Pr
.1
78 to Pr
.189 se
ttin
g
0
RL
Low-speed operation command/
remote setting
Clear/Stop-on-contact selection 0
NET
EXT
NET
EXT
Pr.59
="0" (multi-
speed)
Pr.59
"0" (remote)
Pr.270
="1, 3, 11, or
13" (stop-on-contact)
1
RM
Middle-speed operation
command/remote setting
deceleration
NET
EXT
NET
EXT
2
RH
High-speed operation
command/remote
setting acceleration
NET
EXT
NET
EXT
3
RT
Second function selection/stop-
on-contact selection 1
NET
EXT
Pr.270
="1, 3, 11, or
13" (stop-on-contact)
4
AU
Terminal 4 input selection
―
Combined
―
Combined
5
JOG
Jog operation selection
―
EXT
6
CS
Selection of automatic restart
after instantaneous power
failure, flying start
EXT/ NET
EXT
EXT/ NET is selected
according to
Pr.162
setting.
7
OH
External thermal relay input
EXT
8
REX
15-speed selection
NET
EXT
NET
EXT
Pr.59
="0" (multi-
speed)
9
X9
Third function selection
NET
EXT
10
X10
Inverter run enable signal
EXT
11
X11
FR-CC2 connection,
instantaneous power failure
detection
EXT
12
X12
PU operation external interlock
EXT
13
X13
External DC injection brake
operation start
NET
EXT
14
X14
PID control valid terminal
NET
EXT
NET
EXT
15
BRI
Brake opening completion
signal
NET
EXT
16
X16
PU/External operation
switchover
EXT
17
X17
Load pattern selection forward/
reverse rotation boost
NET
EXT
18
X18
V/F switchover
NET
EXT
19
X19
Load torque high-speed
frequency
NET
EXT
20
X20
S-pattern acceleration/
deceleration C switchover
NET
EXT
22
X22
Orientation command
NET
EXT
23
LX
Pre-excitation/servo ON
NET
EXT
24
MRS
Output stop
Combined
EXT
Pr.79
≠
"7"
PU operation interlock
EXT
Pr.79
= "7"
When X12 signal is
not assigned.
25
STP
(STOP)
Start self-holding selection
-
EXT
26
MC
Control mode switchover
NET
EXT
27
TL
Torque limit selection
NET
EXT