(H) Protective function parameter
316
5.10
(H) Protective function parameter
Purpose
Parameter to set
Refer to
page
To protect the motor from
overheating
Electronic thermal O/L
relay
P.H000, P.H006,
P.H010, P.H016,
P.H020 to P.H022
Pr.9, Pr.51,
Pr.561, Pr.607,
Pr.608, Pr.876,
Pr.1016
To set the overheat protection
characteristics for the motor
Free thermal O/L relay
setting
P.H001 to P.H005,
P.H011 to P.H015
Pr.600 to Pr.604,
Pr.692 to Pr.696
To decelerate and stop when the
motor thermal protection is
activated
Fault definition
P.H030
Pr.875
To extend the life of the cooling fan
Cooling fan operation
selection
P.H100
Pr.244
To detect ground fault at start
Ground fault at start
enable/disable
P.H101
Pr.249
To initiate an inverter protective
function
Fault initiation
P.H103
Pr.997
To disable the I/O phase loss
protective function
I/O phase loss
protection selection
P.H200, P.H201
Pr.251, Pr.872
To restart using the retry function
when the protective function is
activated
Retry operation
P.H300 to P.H303
Pr.65, Pr.67 to
Pr.69
To set the upper and lower limits of
the output frequency
Maximum/minimum
frequency
P.H400 to P.H402
Pr.1, Pr.2, Pr.18
To prevent the motor from
overspeeding under torque control
Speed limit
P.H410 to P.H412
Pr.807 to Pr.809
To avoid overdriving the motor
during speed control
Overdriving prevention
P.H415 to P.H417
Pr.285, Pr.853,
Pr.873
To operate by avoiding resonance
points
Frequency jump
P.H420 to P.H425,
P.H429
Pr.31 to Pr.36,
Pr.552
To limit the output current so that
the inverter protective function
does not activate
Stall prevention
P.H500, P.H501,
P.H600 to P.H603,
P.H610, P.H611,
P.H620, P.H621,
P.H631, P.M430,
P.T010, P.T040
Pr.22, Pr.23,
Pr.48, Pr.49,
Pr.66, Pr.114,
Pr.115, Pr.148,
Pr.149, Pr.154,
Pr.156, Pr.157,
Pr.858, Pr.868
To limit the torque during speed
control
Torque limit
P.H500,
P.H700 to P.H704,
P.H710, P.H720,
P.H721, P.H730,
P.T010, P.T040,
P.G210
Pr.22, Pr.801,
Pr.803, Pr.810,
Pr.812 to Pr.817,
Pr.858, Pr.868,
Pr.874
To monitor for load faults
Load characteristics
fault detection
P.H520 to P.H527,
P.H531 to P.H535
Pr.1480 to
Pr.1492
To shut off the output during
acceleration
Overspeed detection
level
P.H800
Pr.374
To shut off the output when
deceleration is not possible
Deceleration check
P.H880
Pr.690