(N) Operation via communication and its settings
580
• Real-time monitor
Refer to
for the register numbers and monitored items of the real time monitor.
• Parameters
Pr.
Register
Name
Read/Write
Remarks
0 to 999
41000 to
41999
For details on parameter names, refer
to the parameter list (
).
Read/Write
The parameter 41000 is the register number.
902
41902
Terminal 2 frequency setting bias
(frequency)
Read/Write
902
42092
Terminal 2 frequency setting bias
(analog value)
Read/Write
Analog value (%) set to
Pr.902
43902
Terminal 2 frequency setting bias
(terminal analog value)
Read
Analog value (%) of voltage (current) applied to
terminal 2
125 (903)
41903
Terminal 2 frequency setting gain
(frequency)
Read/Write
903
42093
Terminal 2 frequency setting gain
(analog value)
Read/Write
Analog value (%) set to
Pr.903
43903
Terminal 2 frequency setting gain
(terminal analog value)
Read
Analog value (%) of voltage (current) applied to
terminal 2
904
41904
Terminal 4 frequency setting bias
(frequency)
Read/Write
904
42094
Terminal 4 frequency setting bias
(analog value)
Read/Write
Analog value (%) set to
Pr.904
43904
Terminal 4 frequency setting bias
(terminal analog value)
Read
Analog value (%) of current (voltage) applied to
terminal 4
126 (905)
41905
Terminal 4 frequency setting gain
(frequency)
Read/Write
905
42095
Terminal 4 frequency setting gain
(analog value)
Read/Write
Analog value (%) set to
Pr.905
43905
Terminal 4 frequency setting gain
(terminal analog value)
Read
Analog value (%) of current (voltage) applied to
terminal 4
917
41917
Terminal 1 bias frequency (speed)
Read/Write
917
42107
Terminal 1 bias (speed)
Read/Write
Analog value (%) set to
Pr.917
43917
Terminal 1 bias (speed)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 1
918
41918
Terminal 1 gain frequency (speed)
Read/Write
918
42108
Terminal 1 gain (speed)
Read/Write
Analog value (%) set to
Pr.918
43918
Terminal 1 gain (speed)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 1
919
41919
Terminal 1 bias command (torque)
Read/Write
919
42109
Terminal 1 bias (torque)
Read/Write
Analog value (%) set to
Pr.919
43919
Terminal 1 bias (torque)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 1
920
41920
Terminal 1 gain command (torque)
Read/Write
920
42110
Terminal 1 gain (torque)
Read/Write
Analog value (%) set to
Pr.920
43920
Terminal 1 gain (torque)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 1
926
41926
Terminal 6 bias frequency (speed)
Read/Write
926
42116
Terminal 6 bias (speed)
Read/Write
Analog value (%) set to
C31 (926)
43926
Terminal 6 bias (speed)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6 of the
FR-A8AZ
927
41927
Terminal 6 gain frequency (speed)
Read/Write
927
42117
Terminal 6 gain (speed)
Read/Write
Analog value (%) set to
C33 (927)
43927
Terminal 6 gain (speed)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6 of the
FR-A8AZ
928
41928
Terminal 6 bias command (torque)
Read/Write
928
42118
Terminal 6 bias (torque)
Read/Write
Analog value (%) set to
C35 (928)
43928
Terminal 6 bias (torque)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6 of the
FR-A8AZ
929
41929
Terminal 6 gain command (torque)
Read/Write
929
42119
Terminal 6 gain (torque)
Read/Write
Analog value (%) set to
C37 (929)
43929
Terminal 6 gain (torque)
(terminal analog value)
Read
Analog value (%) of voltage applied to terminal 6 of the
FR-A8AZ
932
41932
Terminal 4 bias command (torque)
Read/Write
Содержание 800 Series
Страница 11: ...MEMO 10 ...
Страница 17: ...MEMO 16 ...
Страница 95: ...MEMO 94 ...
Страница 671: ...MEMO 670 ...
Страница 681: ...MEMO 680 ...