Parameter List
Parameter list (by function group)
124
M: Monitor display and monitor output signal
Parameters regarding the inverter's operating status. These
parameters are used to set the monitors and output signals.
H603
115
Third stall prevention operation
frequency
H610
23
Stall prevention operation level
compensation factor at double speed
H611
66
Stall prevention operation reduction
starting frequency
H620
148
Stall prevention level at 0 V input
H621
149
Stall prevention level at 10 V input
H631
154
Voltage reduction selection during stall
prevention operation
H700
810
Torque limit input method selection
H701
812
Torque limit level (regeneration)
H702
813
Torque limit level (3rd quadrant)
H703
814
Torque limit level (4th quadrant)
H704
801
Output limit level
H710
815
Torque limit level 2
H720
816
Torque limit level during acceleration
H721
817
Torque limit level during deceleration
H730
874
OLT level setting
H800
374
Overspeed detection level
H881
690
Deceleration check time
Pr.
group
Pr.
Name
Refer
to page
M000
37
Speed display
M001
505
Speed setting reference
M002
144
Speed setting switchover
M020
170
Watt-hour meter clear
M021
563
Energization time carrying-over times
M022
268
Monitor decimal digits selection
M023
891
Cumulative power monitor digit
shifted times
M030
171
Operation hour meter clear
M031
564
Operating time carrying-over times
M040
55
Frequency monitoring reference
M041
56
Current monitoring reference
M042
866
Torque monitoring reference
M043
241
Analog input display unit switchover
M044
290
Monitor negative output selection
M045
1018
Monitor with sign selection
M050
1106
Torque monitor filter
M051
1107
Running speed monitor filter
M052
1108
Excitation current monitor filter
M060
663
Control circuit temperature signal
output level
M100
52
Operation panel main monitor
selection
M101
774
Operation panel monitor selection 1
M102
775
Operation panel monitor selection 2
M103
776
Operation panel monitor selection 3
M104
992
Parameter for manufacturer setting. Do not set.
M200
892
Load factor
M201
893
Energy saving monitor reference
(motor capacity)
M202
894
Control selection during commercial
power-supply operation
M203
895
Power saving rate reference value
M204
896
Power unit cost
M205
897
Power saving monitor average time
M206
898
Power saving cumulative monitor
clear
Pr.
group
Pr.
Name
Refer
to page
M207
899
Operation time rate (estimated value)
M300
54
FM terminal function selection
M301
158
AM terminal function selection
M310
900
FM terminal calibration
M320
901
AM terminal calibration
M321
867
AM output filter
M400
190
RUN terminal function selection
M401
191
SU terminal function selection
M402
192
IPF terminal function selection
M403
193
OL terminal function selection
M404
194
FU terminal function selection
M405
195
ABC1 terminal function selection
M406
196
ABC2 terminal function selection
M410
DO0 output selection
M411
DO1 output selection
M412
DO2 output selection
M413
DO3 output selection
M414
DO4 output selection
M415
DO5 output selection
M416
DO6 output selection
M420
RA1 output selection
M421
RA2 output selection
M422
RA3 output selection
M430
157
OL signal output timer
M431
289
Inverter output terminal filter
M433
166
Output current detection signal
retention time
M440
870
Speed detection hysteresis
M441
41
Up-to-frequency sensitivity
M442
42
Output frequency detection
M443
43
Output frequency detection for
reverse rotation
M444
50
Second output frequency detection
M445
116
Third output frequency detection
M446
865
Low speed detection
M460
150
Output current detection level
M461
151
Output current detection signal delay
time
M462
152
Zero current detection level
M463
153
Zero current detection time
M464
167
Output current detection operation
selection
M470
864
Torque detection
M500
495
Remote output selection
M501
496
Remote output data 1
M502
497
Remote output data 2
M510
76
Fault code output selection
M520
799
Pulse increment setting for output
power
M530
655
Analog remote output selection
M531
656
Analog remote output 1
M532
657
Analog remote output 2
M533
658
Analog remote output 3
M534
659
Analog remote output 4
M600
Control terminal option-Encoder pulse
division ratio
M601
Encoder pulse division ratio
M610
Cumulative pulse clear signal
selection
M611
Cumulative pulse division scaling
factor
M612
Control terminal option-Cumulative
pulse division scaling factor
M613
Cumulative pulse storage
Pr.
group
Pr.
Name
Refer
to page
Содержание 800 Series
Страница 11: ...MEMO 10 ...
Страница 17: ...MEMO 16 ...
Страница 95: ...MEMO 94 ...
Страница 671: ...MEMO 670 ...
Страница 681: ...MEMO 680 ...