(M) Monitor display and monitor output signal
357
5
GROUP
M
5.11.3
Monitor display selection for terminals FM and
AM
FR-A860-01080 or lower.
FR-A860-01440 or more.
Function assigned to
Pr.185 JOG terminal function selection
.
The monitored statuses can be output as the following items: analog voltage (terminal AM), pulse train (terminal FM).
The signal (monitored item) to be output to terminal FM and terminal AM can be selected.
Pr.
Name
Initial value
Setting range
Description
54
M300
FM terminal function
selection
1
(output
frequency)
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 36,
46, 50, 52, 53, 61, 62,
67, 70, 87 to 90, 92,
93, 95, 97, 98
Select the monitored item to be output to
the terminal FM.
158
M301
AM terminal function
selection
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 36,
46, 50, 52 to 54, 61,
62, 67, 70, 87 to 98
Select the monitored item to be output to
the terminal AM.
55
M040
Frequency monitoring
reference
60 Hz
0 to 590 Hz
Set the full-scale value when outputting
the frequency monitor value to terminals
FM and AM.
56
M041
Current monitoring reference
Inverter
Rated current
0 to 500 A
Set the full-scale value when outputting
the output current monitor value to
terminals FM and AM.
0 to 3600 A
866
M042
Torque monitoring reference
150%
0 to 400%
Set the full-scale value when outputting
the torque monitor value to terminals FM
and AM.
290
M044
Monitor negative output
selection
0
0 to 7
Set the availability of output with a minus
sign for the terminal AM, the operation
panel display, or monitoring via
communication. (Refer to
291
D100
Pulse train I/O selection
0
Pulse train
input
(terminal JOG)
Pulse train
output
(terminal FM)
0
JOG signal
FM output
1
Pulse train input
FM output
10
JOG signal
High-speed pulse
train output
(50% duty)
11
Pulse train input
High-speed pulse
train output
(50% duty)
20
JOG signal
High-speed pulse
train output
(ON width fixed)
21
Pulse train input
High-speed pulse
train output
(ON width fixed)
100
Pulse train input
High-speed pulse
train output
(ON width fixed)
Output the pulse
train input without
changes.