(M) Monitor display and monitor output signal
355
5
GROUP
M
Minus sign display for the monitors (Pr.290)
• A negative output can be selected for the monitor display of the terminal AM (analog voltage output), the operation panel,
and a communication option. For a list of the monitors that can output values with minus signs, refer to the monitor
description list (on
• Negative output is available for FR Configurator2 or the trace function.
—: Disabled (unsigned numbers only)
The following communication does not support the negative output.
RS-485 communication (Mitsubishi inverter protocol, MODBUS RTU), SLMP communication, and HMS network option
Under the condition that the high-speed sampling and the negative output are selected for FR Configurator2, the display range of the output
frequency (Monitor No.1) is -300.00 Hz to 300.00 Hz. A value outside the range is clamped at -300.00 Hz or 300.00 Hz. Under the same
condition, the display range of the running speed (Monitor No.6) is -30000 r/min to 30000 r/min. A value outside the range is clamped at -30000
r/min or 30000 r/min. During the trace sampling, the same display ranges are applied. A value outside the ranges is clamped.
• Select items to be displayed with minus signs using
Pr.1018 Monitor with sign selection
.
○
: Displayed with minus signs, —: Displayed without minus signs (unsigned numbers only)
Displayed without minus signs on the operation panel. Confirm the rotation direction with the [FWD] or [REV] indicator.
Signed values are displayed only on the FR-DU08 (-9999 to 9999). Unsigned values (0 to 9999) are displayed on other devices.
Full 32-bit data (-2147483648 to 2147483647) is displayed during monitoring via the communication option.
Monitor the lower and upper digits at the same timing. Otherwise, the data may not be reliable.
Pr.290 setting
Connection port
Terminal AM
Operation panel
Communication option
FR Configurator2 etc.
0 (initial value)
—
—
—
—
1
Enabled
—
—
—
2
—
Enabled
—
—
3
Enabled
Enabled
—
—
4
—
—
Enabled
Enabled
5
Enabled
—
Enabled
Enabled
6
—
Enabled
Enabled
Enabled
7
Enabled
Enabled
Enabled
Enabled
Monitor item
Pr.1018 setting
9999
0
1
Output frequency
—
○
Motor speed
—
○
Motor torque
○
○
○
Position command (lower)
○
Position command (upper)
○
Current position (lower)
○
Current position (upper)
○
Droop pulse (lower)
○
Droop pulse (upper)
○
Torque command
○
○
○
Torque current command
○
○
○
Torque monitor (power driving / regenerative driving
polarity switching)
○
○
○
Motor temperature
○
○
○
PID deviation
○
○
○
Cumulative pulse
○
○
○
Cumulative pulse overflow times
○
○
○
Cumulative pulse (control terminal option)
○
○
○
Cumulative pulse overflow times (control terminal option)
○
○
○
Remote output 1
○
○
○
Remote output 2
○
○
○
Remote output 3
○
○
○
Remote output 4
○
○
○
PID manipulated amount
○
○
○
Second PID deviation
○
○
○
Second PID manipulated amount
○
○
○
Control circuit temperature
○
○
○