(G) Control parameters
596
• When
Pr.14
= "14 or 15" and the X17 signal is turned ON, the excitation current scaling factor is switched from the value set
in
Pr.617
to the value set in
Pr.86
.
• An excitation current low-speed scaling factor set in the parameter shown in the table is used according to the
Pr.14
setting
and other conditions.
Pr.14 setting
X17 signal
During forward rotation
During reverse rotation
RT signal OFF
RT signal ON
RT signal OFF
RT signal ON
0 to 5
—
Pr.86
Pr.566
Pr.86
Pr.566
12
—
Pr.86
Pr.566
Pr.617
Pr.617
13
—
Pr.617
Pr.617
Pr.86
Pr.566
14
OFF
Pr.86
Pr.566
Pr.617
Pr.617
ON
Pr.86
Pr.566
Pr.86
Pr.566
15
OFF
Pr.617
Pr.617
Pr.86
Pr.566
ON
Pr.86
Pr.566
Pr.86
Pr.566