Encoder feedback control
Setting before operation (Pr.144, Pr.359, Pr.369)
• When driving with V/F control and the encoder feedback control, set the number of motor poles in
Pr.144 Speed setting
switchover
in accordance with the applied motor. During Advanced magnetic flux vector, the
Pr.81 Number of motor
poles
setting is used, so the
Pr.144
setting does not need to be changed.
• Using
Pr.359 Encoder rotation direction
and
Pr.369 Number of encoder pulses
, set the rotation direction and the
number of pulses for the encoder.
NOTE
• When the inverter is operated with
Pr.144
= "0, 10, 12, 110, 112", it will cause E.1 to E.3.
• When set to
Pr.144
= "102, 104, 106, 108", number with 100 subtracted will be set as the number of poles.
• When
Pr.81
is set, setting value for
Pr.144
will be automatically changed, but even if
Pr.144
is changed,
Pr.81
will not
automatically change.
• Control with correct speed is not possible if the number of poles for the applied motor is incorrect. Make sure to confirm
before operation.
• Encoder feedback control is not possible when the rotation direction setting of the encoder is incorrect. (Operation of the
inverter is possible.)
Confirm with the rotation direction indicator on the parameter unit.
By detecting the rotation speed of the motor with the speed detector (encoder) and feeding it back to the inverter,
output frequency of the inverter is controlled to keep the speed of the motor constant even for the load change.
Vector control compatible option is required.
Pr.
Name
Initial
value
Setting
range
Description
144
M002
Speed setting
switchover
4
0, 2, 4, 6, 8,
10, 12, 102,
104, 106, 108,
110, 112
Set the number of motor poles for the operation by V/F
control and the encoder feed control.
285
H416
Overspeed detection
frequency
9999
0 to 30 Hz
When the difference between the detected frequency and
the output frequency exceeds the set value at the time of
encoder feedback control, an inverter fault (E.MB1) is
generated.
9999
Overspeed detection disabled.
359
C141
852
C241
Encoder rotation
direction
1
0
Set when using a motor for
which forward rotation
(encoder) is clockwise
(CW) viewed from the shaft
Set for the operation at
120 Hz or less.
100
Set for the operation at a
frequency higher than 120
Hz.
1
Set when using a motor for
which forward rotation
(encoder) is
counterclockwise (CCW)
viewed from the shaft
Set for the operation at
120 Hz or less.
101
Set for the operation at a
frequency higher than 120
Hz.
367
G240
Speed feedback range
9999
0 to 590 Hz
Set the range of speed feedback control.
9999
Disables encoder feedback control
368
G241
Feedback gain
1
0 to 100
Set when the rotation is unstable or response is slow.
369
C140
851
C240
Number of encoder
pulses
1024
0 to 4096
Set the number of encoder pulses output.
Set the number of pulses before it is multiplied by 4.
The speed deviation excess detection frequency is used when vector control compatible option is mounted and vector control is performed.
(For the details, refer to
.)
These parameters are available when vector control compatible option is installed.
The parameter number is the one for use a Vector control compatible option. (
Pr.369
is applicable for the FR-A8AP and FR-A8AL.)
The parameter number is the one for use with the control terminal option (FR-A8TP).
V/F
V/F
V/F
Magnetic flux
Magnetic flux
Magnetic flux
CW
CCW
Содержание 800 Series
Страница 11: ...MEMO 10 ...
Страница 17: ...MEMO 16 ...
Страница 95: ...MEMO 94 ...
Страница 671: ...MEMO 670 ...
Страница 681: ...MEMO 680 ...