SFP+ 1 Bias Low Alarm threshold = 2.600mA
SFP+ 1 TX Power Low Alarm threshold = 0.158mW
SFP+ 1 RX Power Low Alarm threshold = 0.040mW
===================================
SFP+ 1 Temp High Warning threshold = 75.000C
SFP+ 1 Voltage High Warning threshold = 3.630V
SFP+ 1 Bias High Warning threshold = 8.500mA
SFP+ 1 TX Power High Warning threshold = 0.741mW
SFP+ 1 RX Power High Warning threshold = 1.259mW
SFP+ 1 Temp Low Warning threshold = -5.000C
SFP+ 1 Voltage Low Warning threshold = 2.970V
SFP+ 1 Bias Low Warning threshold = 3.000mA
SFP+ 1 TX Power Low Warning threshold = 0.178mW
SFP+ 1 RX Power Low Warning threshold = 0.063mW
===================================
SFP+ 1 Temperature = 34.988C
SFP+ 1 Voltage = 3.281V
SFP+ 1 Tx Bias Current = 6.746mA
SFP+ 1 Tx Power = 0.635mW
SFP+ 1 Rx Power = 0.002mW
===================================
SFP+ 1 Data Ready state Bar = False
SFP+ 1 Rx LOS state = True
SFP+ 1 Tx Fault state = False
SFP+ 1 Rate Select state = True
SFP+ 1 RS state = False
SFP+ 1 Tx Disable state = False
===================================
SFP+ 1 Temperature High Alarm Flag = False
SFP+ 1 Voltage High Alarm Flag = False
SFP+ 1 Tx Bias High Alarm Flag = False
SFP+ 1 Tx Power High Alarm Flag = False
SFP+ 1 Rx Power High Alarm Flag = False
SFP+ 1 Temperature Low Alarm Flag = False
SFP+ 1 Voltage Low Alarm Flag = False
SFP+ 1 Tx Bias Low Alarm Flag = False
SFP+ 1 Tx Power Low Alarm Flag = False
SFP+ 1 Rx Power Low Alarm Flag = True
===================================
SFP+ 1 Temperature High Warning Flag = False
SFP+ 1 Voltage High Warning Flag = False
SFP+ 1 Tx Bias High Warning Flag = False
SFP+ 1 Tx Power High Warning Flag = False
SFP+ 1 Rx Power High Warning Flag = False
SFP+ 1 Temperature Low Warning Flag = False
SFP+ 1 Voltage Low Warning Flag = False
SFP+ 1 Tx Bias Low Warning Flag = False
SFP+ 1 Tx Power Low Warning Flag = False
SFP+ 1 Rx Power Low Warning Flag = True
Related
Commands
•
— configures a physical interface on the switch.
•
— displays Layer 3 information about the interface.
•
— displays information on a specific physical interface or virtual
interfaces.
•
— displays the switch type, components (including media), Dell
Networking OS version including hardware identification numbers and configured
protocols.
Interfaces
1003
Содержание C9000 series
Страница 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Страница 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Страница 877: ...algorithm FIPS Cryptography 877 ...
Страница 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...
Страница 1711: ...Vl 200 Dell Policy based Routing PBR 1711 ...
Страница 2277: ...Example Dell show run vrf test3 ip vrf test3 description IT Department Virtual Routing and Forwarding VRF 2277 ...