![Dell C9000 series Скачать руководство пользователя страница 118](http://html.mh-extra.com/html/dell/c9000-series/c9000-series_reference-manual_23045118.webp)
Alarm Type Duration
---------------------------------------------------------------------------
PEM 0 in unit 0 down 25 sec
PEM 2 in unit 0 down 6 sec
Dell#show alarm threshold
-- Temperature Limits (deg C) --
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard0 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard1 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard2 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard3 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard4 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard5 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard6 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard7 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard8 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
RPM0 35 40 43 48 NA
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
RPM1 35 40 43 48 NA
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
PEid0/Stack0 60 65 72 75 105
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
PEid0/Stack2 60 65 72 75 105
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
PEid0/Stack3 60 65 72 75 105
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
PEid0/Stack4 60 65 72 75 105
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
PEid0/Stack5 60 65 72 75 105
Control and Monitoring
118
Содержание C9000 series
Страница 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Страница 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Страница 877: ...algorithm FIPS Cryptography 877 ...
Страница 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...
Страница 1711: ...Vl 200 Dell Policy based Routing PBR 1711 ...
Страница 2277: ...Example Dell show run vrf test3 ip vrf test3 description IT Department Virtual Routing and Forwarding VRF 2277 ...