Command Modes
• EXEC
• EXEC Privilege
Defaults
Display detailed information on CPU usage for all switch CPUs (control processor, route
processor, and linecards).
Command History This guide is platform-specific. For command information about other platforms, see the
relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.9(0.0)
Introduced on the C9010.
9.2(1.0)
Introduced on the Z9500.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.5.1.0
Introduced on the C-Series.
Usage Information The following examples display CPU usage information for the control processor (CP), route
procesor (RP), and the port extender (PE).
Example show
processes cpu cp
Dell#sho processes cpu cp
CPUID 5sec 1min 5min
-------- ---------- ----------- -----------
CORE 0 0.59 1.18 0.00
CORE 2 0.20 0.44 0.00
Overall 0.40 0.81 0.00
CPU utilization of sysdlp for five seconds: 0%/0%; one minute: 0%; five minutes: 0%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
0x000001ef 181290 18129 10000 0.20% 0.20% 0.20% 0 sysdlp
0x0000020c 182530 18253 10000 0.10% 0.17% 0.23% 0 sysd
0x00000000 171610 17161 10000 0.05% 0.16% 0.25% 0 system
0x0000013f 7550 755 10000 0.05% 0.02% 0.01% 0 dot1x
0x0000027c 12300 1230 10000 0.05% 0.02% 0.01% 0 sflow
0x0000020f 5210 521 10000 0.00% 0.02% 0.01% 0 f10dhclient
0x00000137 5160 516 10000 0.00% 0.02% 0.00% 0 ndpmul
0x000002f1 7730 773 10000 0.00% 0.02% 0.01% 0 Dhcpv6Rly
0x00000073 4920 492 10000 0.00% 0.02% 0.00% 0 ipSecMgr
0x00000291 5500 550 10000 0.00% 0.02% 0.01% 0 ssMgr
0x00000244 5370 537 10000 0.00% 0.01% 0.00% 0 ntp
0x00000265 5180 518 10000 0.00% 0.01% 0.00% 0 f10dhcpv4rly
0x000002bd 4950 495 10000 0.00% 0.01% 0.00% 0 otm
0x00000099 15360 1536 10000 0.00% 0.01% 0.02% 0 brm
0x000002ce 7220 722 10000 0.00% 0.01% 0.03% 0 clish
0x000000f5 5000 500 10000 0.00% 0.01% 0.00% 0 vlthrtbtrly
0x000000e3 5480 548 10000 0.00% 0.01% 0.00% 0 tnlmgr
0x00000249 6620 662 10000 0.00% 0.01% 0.01% 0 ipm
0x00000228 12430 1243 10000 0.00% 0.00% 0.02% 0 radius
0x000002bb 8380 838 10000 0.00% 0.00% 0.01% 0 ofmgr
0x000001f8 640 64 10000 0.00% 0.00% 0.00% 0 sysmon
0x000001f4 1090 109 10000 0.00% 0.00% 0.00% 0 sysmon
0x000000df 3140 314 10000 0.00% 0.00% 0.00% 0 flashmntr
0x000000d7 0 0 0 0.00% 0.00% 0.00% 0 inetd
0x00000095 750 75 10000 0.00% 0.00% 0.00% 0 rngd
0x00000079 40 4 10000 0.00% 0.00% 0.00% 0 sh
0x00000043 10 1 10000 0.00% 0.00% 0.00% 0 sh
0x00000013 610 61 10000 0.00% 0.00% 0.00% 0 mount_mfs
0x00000002 40 4 10000 0.00% 0.00% 0.00% 0 sh
Control and Monitoring
145
Содержание C9000 series
Страница 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Страница 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Страница 877: ...algorithm FIPS Cryptography 877 ...
Страница 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...
Страница 1711: ...Vl 200 Dell Policy based Routing PBR 1711 ...
Страница 2277: ...Example Dell show run vrf test3 ip vrf test3 description IT Department Virtual Routing and Forwarding VRF 2277 ...