CHAPTER 30:FPD-Link Converter
1132
S6J3200 Series Hardware Manual Document Number: 002-04852 Rev. *G
[bit4] INV :Invert
Configures the setting of the Inversion function of the data selected by RX_NUM.
Bit
Description
0
Disable(default)
1
Enable
[bit3] Reserved
Always write "0" to this bit. The read value is "0".
[bit2:0] RX_NUM[2:0] :RX number
Selects data to be output to TXn (n= 0 to 4).
Bits
Description
000
RX0
001
RX1
010
RX2
011
RX3
100
RX4
101
IMD_DAT
110
IMD_DAT
111
IMD_DAT (default)