Deceleration/Acceleration Potentiometers
The deceleration and acceleration potentiometers (Figure 7-10) provide a means of adjusting the length of time it
takes for the motor to accelerate (Accel) and decelerate (Decel) in response to parent machine speed changes. Both
potentiometers should be positioned fully counterclockwise.
deceleration
potentiometer
Figure 7-10. Deceleration/Acceleration Potentiometer
accceleration
potentiometer