- 1 -
Q
uick
S
tart
G
uide
VC350AG AutoGlue Control System
Congratulations on purchasing the Valco VC350AG AutoGlue Control
System. This Quick Start Guide provides step-by-step system setup
instructions. Your VC350AG arrives ready-to-mount and ready-to-run.
This logic-controlled unit is designed to operate with the Valco
BOARDRUNNER Glue Station or other compatible scanner/valve
combinations.
Contents
Unpacking the VC350AG Control ……………….
1
Mounting the Control …………………………….
1
Mounting the Encoder ……………………………
2
Installing the BOARDRUNNER Glue Station …
2
Connecting the Cables …………………………..
3
Checking Settings …………………………………
4
Running the VC350AG Control …………………..
4
Unpacking the VC350AG Control
When the VC350AG Control arrives, open the shipping container and carefully remove all boxes and box contents.
The contents include the following items:
• VC350AG Control Body
• Encoder Assembly
• Cables
• BOARDRUNNER Glue Station
• Installation Kit (includes 5/16” (8mm) hex wrench and mounting bracket
Mounting the Control
The VC350AG is shipped with a wall-type mounting bracket. The unit can be mounted to almost any flat surface on
the operator side of the parent machine, provided that there is sufficient space and easy access to the control. You
should also position the control in a place with minimum vibration. The control should require less than 25 feet of
wiring to reach the glue station, sensor, and encoder.
Follow these steps to mount the control:
1. Install wall-mounting rail to machine wall.
2. Install ¼-20 x 1.5” socket head capscrew into
wall-mounting rail.
3. Use the ¼-20 x ½” socket head capscrews to install
cabinet-mounting rail to the upper set of mounting
holes in the rear of the cabinet.
4. Make sure slot in the rail is facing away from the cabinet.
5. Use ¼-20 x ½” socket head capscrews to install mounting
spacers (2) to the lower set of holes in the rear of the cabinet.
6. Slide cabinet rail over the wall rail so mounting rails interlock.
7. Tighten ¼-20 x 1.5” socket head capscrew to secure rails.
8. (Optional) Additional holes can be drilled into machine wall to
secure the two mounting spacers to the wall as well.
Cabinet
Mounting Rail
Mounting Spacers
Back of Cabinet
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...