7-14
Valco Cincinnati, Inc.
Section 7 - Initial Setup
MC060 Manual/VC350AG AutoGlue Control System
minimum-speed potentiometer
Figure 7-8. Minimum-Speed Potentiometer
For manual mode only. To adjust the maximum-speed potentiometer (Figure
7-9), follow these steps:
1.
Switch the AutoGlue selector switch to the off position.
2.
Turn the glue flow knob on the hot-melt unit to the full clockwise
position.
3.
Adjust the maximum speed potentiometer to the desired motor
speed. (A clockwise rotation will increase the motor speed.)
WARNING!
WARNING!
WARNING!
WARNING!
WARNING! Do not exceed 180VDC armature voltage (circuit board
terminals A1 and A2). OTHERWISE, DEATH,
PERSONAL INJURY, OR EQUIPMENT DAMAGE
COULD OCCUR.
The minimum speed adjustment will
affect the maximum speed setting.
Therefore, it is necessary to readjust
the maximum speed after the minimum
speed has been adjusted. It may also
be necessary to repeat the operations
until both the minimum and maximum
speeds are set to the desired levels.
Maximum-Speed
Potentiometer
Minimum-Speed Potentiometer -
Continued