8-1
Valco Cincinnati, Inc.
SECTION 8 - OPERATION
SECTION 8 - OPERATION
SECTION 8 - OPERATION
SECTION 8 - OPERATION
SECTION 8 - OPERATION
This section contains operating instructions for the VC350AG AutoGlue
Control system.
To set up a job, follow these steps:
1.
Measure the distance from the leading edge of the tab (first
edge seen by the scanner) to the point at which the glue pattern
should begin (Figure 8-1).
2.
Enter this dimension as the “Start” value on the front panel of
the control unit (Figure 8-2). Value of 01.00 as shown in the
figure below.
3.
Measure the distance from the back edge of the tab to the point
at which the glue pattern should stop (Figure 8-3).
4.
Enter this dimension as the “Stop” value on the front panel of the
control unit (Figure 8-2). Value of 01.00 as shown in Figure 8-3.
Job Setup for
AutoGlue
Figure 8-1. Glue-Start Measurement
1 2 3 4 5 6 7 8
Product Flow