B-5
Valco Cincinnati, Inc.
MC060 Manual/VC350AG AutoGlue Control System
Appendix B - Quick Start Guide
Complete the following steps to set up the VC350AG Control to operate with
the BOARDRUNNER Glue Station.
1.
Set the glue-flow knob on the front panel of the control to the
middle position (12 o’clock).
2.
Turn on the electrical power to the control unit.
3.
Put the AutoGlue Switch in the UP position/LED on.
4.
Set the front-panel “Start” and “End” switches in order to apply a
sample glue pattern of .50 and .50. Run a box at slow speed.
4a.
Measure the distance from the leading edge of the
tab (first edge seen by scanner) to the point at which
the glue pattern begins. (Dimension a)
4b.
Divide the measurement by .50. Put that number in
the ratio compensation switch. Measure the
distance from the back tab edge (last edge seen by
scanner) to the point at which the pattern stops.
(Dimension b)
Running the
VC350AG
Control
a
b
Step 4
Dimension a
Dimension b
On delay
Ratio compensation switches
Off delay