6-16
Valco Cincinnati, Inc.
Section 6 - Installation
MC060 Manual/VC350AG AutoGlue Control System
Available cables used to connect the glue valve(s) to the VC350AG are listed
in Section 12—
Part Number List.
The VC350AG will ONLY fire 12VDC
valves!
To connect the glue valve to the control, secure the female end of the cable
(blue ends) to the glue valve (or connector cable). Then, connect the male
end of the cable to the Glue Valve 1 blue connector on the bottom of the
VC350AG control.
The valve driver board JP1 can be
moved to the 1-2 position to fire two
valves with identical patterns. In this
case, you need a second valve and
cable. See Figure 6-11.
Figure 6-11. Valve-Driver Board
Electrical Installation
of the Glue Valve
Glue Valve Installation for
a One-Channel System
Valve selection jumper; JP1