Valco Cincinnati
8-1
Introduction
This section contains instructions for operating the VC350A.
Job Setup
To set up a job, follow these steps:
1. Measure the distance from the leading edge of the product (first edge seen by the scanner) to the point at
which the glue pattern should begin (Figure 8-1).
2. Enter this dimension as the “Flap” value on the front panel of the control unit (Figure 8-2).
Note!
Values can be entered as follows:
1000-line encoder:
99.99 inches
250/500-line encoder:
999.9 inches or 9999mm
3. Measure the distance from the leading edge (first edge seen by the scanner) to the point at which the glue
pattern should stop (Figure 8-3).
4. Enter this dimension as the “Glue” value on the front panel of the control unit (Figure 8-2).
Note!
Values can be entered as follows:
1000-line encoder:
99.99 inches
250/500-line encoder:
999.9 inches or 9999mm
Section 8—Operation
Figure 8-1. Glue-Flap Measurement
(25.4 mm)