Section 6
—
Installation
VC350A Flexoseal
®
System
Valco Cincinnati
6-17
Installing the Glue Delivery System
The glue delivery system consists of the following components:
•
DD-1 pump
•
Air filter/regulator
•
Glue filter
•
Glue regulator
•
Glue-pressure gauge
•
Gauge protector
•
Glue-pressure relief system (optional)
Mechanical Installation of the Glue Delivery System
To install the glue delivery system (Figure 6-16), follow these steps:
1. Install a hose on the output of the drop line feeding the glue filter and regulator assembly.
Note!
Use a 1/2" reinforced hose if you are using a diaphragm pump, and a 1/2" high-pressure hose if you
are using a 2:1 or 5:1 piston pump.
2. Attach a 3/8" reinforced hose from the output of the glue regulator to the glue valve.
Note
!
For long runs, position the pump in the middle of the system.
Note
!
Use “T” connections; do not use “L” connections.
Note
!
Keep valve outlets plugged except when using valve to purge system.
The following materials can be used for lateral, drop, and feed lines:
•
Stainless-steel pipe
•
Schedule 40 (black pipe)
•
Schedule 80 PVC (threaded or glued)
3/8"
reinforced
hose
regulator
assembly
1/2" reinforced
or high-pressure hose
drop line
0.5-0.75"
(12-19 mm)
lateral line
1.5-2" (38-51 mm)
purge valve
feed line
1.5-2"
(38-51 mm)
lateral line 1.5-2" (38-51 mm)
purge valve
drop line
0.5-0.75"
(12-19 mm)
optional spare pump
glue station
Figure 6-16. Glue Delivery System
glue filter
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...