Problem
Possible Cause
Possible Solution
Glue Pattern, continued
21. There is insufficient
glue at any speed.
21a.
Glue flow set too low
21b. Fluid pressure regulator set too
low or too high
21c.
Low air pressure supplied to
pump
21d. Obstruction in the glue system
21e.
Obstruction in the glue line
21f.
Dirty applicator head
21g. Glue pressure too high
(actuating air cannot overcome
the glue pressure)
21h. Incorrect angle of applicator
head
21i.
Viscosity of the glue is too high
21j.
EPC solenoids clogged
21a.
Increase glue flow.
21b. Adjust the fluid pressure
regulator.
21c.
Increase air pressure.
21d. Clean the glue filter.
21e.
Flush the glue supply system.
21f.
Clean applicator head.
21g. Reduce glue pressure or
increase air pressure at the
solenoid valve.
21h. Adjust head angle.
21i.
Use glue with 1500-2100 cps
viscosity
21j.
Clean EPC solenoids