Appendix D
—
Maintenance Procedures
VC350A Flexoseal
®
System
Valco Cincinnati
D-2
Weekly Maintenance
Actions
Date
Shift
Initials
1. Clean the glue filter thoroughly with water.
2.
For electric-coil non-contact valves only
—disassemble
the fluid section of the glue valve, and clean the section
thoroughly with water.
3. If you are using a 585 valve, replace the valve spring.
4.
For non-contact valves only
—lubricate the valve with
Teflon oil (supplied with maintenance kit).
5. Reassemble the fluid section.
6. Using the 3-way purge valve on the output of the glue
filter, purge all air from the system.
7. Purge each valve in the system. (Approximately 1-2
ounces of glue should be purged for proper glue flow.)
8. Check for any glue leakage on the needle seat. Replace
the needle/plunger assembly and seat if leaks or
dripping occurs.
9.
For non-contact valves only
—Apply a small amount of
lithium grease to the nozzle seat area before attaching
the retaining nut.
10. Check all quick-disconnect fittings for any dried glue
or swelling that may restrict the glue flow.
11. Lubricate each quick-disconnect fitting with lithium
grease or equivalent.
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...