6-12
Valco Cincinnati, Inc.
Section 6 - Installation
MC060 Manual/VC350AG AutoGlue Control System
The glue application system consists of the following components:
•
Glue station
•
Scanner
•
Glue valves
•
Applicator assembly
When the BOARDRUNNER Glue Station is shipped, it is ready for a 4
th
panel
(drive side) top-down installation. The scanner is initially mounted to view the
product in line with the glue valve. The gap adjustment is set so that a single-
walled product (approx. 3mm thick) can pass through the glue station and
remain in contact with the applicator head.
The Setup Process consists of the following steps:
1. Mount the BOARDRUNNER glue station to the mounting rods.
2. Install the applicator head onto the 900 valve.
3. Purge all air from the glue line, then connect to the valve. Purge
the valve by activating the push button switch on the valve.
Scanner and valve cables must be
connected before any purging can take
place.
4.
Run adhesive through valve until no air is present in the line.
5.
Run the parent machine and Stop when product reaches the
glue station.
Installing the
Glue
Application
System
Glue Stations
Figure 6-9. BOARDRUNNER Glue Station
product flow
scanner
air
cylinder
air inlet
900 valve
applicator
head
Installing the
BOARDRUNNER Glue
Station
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...