6-18
Valco Cincinnati, Inc.
Section 6 - Installation
MC060 Manual/VC350AG AutoGlue Control System
To fire two valves with identical PSP
patterns, switch JP1 on the valve driver
board to the 1-2 position. A second
valve and valve cable will be needed for
this. This can only be done in the PSP
mode!
To install two glue valves dispensing different patterns, follow these steps:
Gun 1, channel I = valve 1. Gun 2,
channel II = valve 2.
1.
Connect glue valve cables to Valve 1 and Valve 2 (see Figure 6-
14).
2.
Set JP1 on the main board to the SC2 position. If two scanners
are used, set JP1 to the SC1 position (scanner 1 controls
channel I, scanner 2 controls channel II).
3.
Set SW6 on the channel II board to the P-S-P position (down).
4.
Set SW7 on the channel II board to the CH2 position (up).
5.
The gun selector switch should be plugged into J36 on the
channel II board.
Glue Valve Installation for a Two-
Channel System - Continued
Figure 6-13. Channel II Board
SW6
SW7
Gun
selector
switch