8-10
Valco Cincinnati, Inc.
Section 8 - Operation
MC060 Manual/VC350AG AutoGlue Control System
11. If the parent machine is at rest and the pressure on the front
gauge is not on “0”, adjust the “zero” pot down to reach zero.
This adjustment should be made by
slowly backing the adjustment down.
Do not adjust the pot so far down that
the “decrease” LED remains on.
Figure 8-9. Fluid-Flow Control (EPC) Manifold
manifold
pressure-gauge port
pressure transducer
increase solenoid
decrease solenoid
Fluid-Flow Control (EPC) (original
version) - Continued
Summary of Contents for VC350A