7-13
Valco Cincinnati, Inc.
MC060 Manual/VC350AG AutoGlue Control System
Section 7 - Initial Setup
The control is now compensated to provide minimal speed change under
large variations of applied load. If the IR compensation is set too high,
unstable motor operation will occur. This will be evident if the motor speed
increases and decreases in a cycle. To correct this problem, rotate the IR
compensation potentiometer counterclockwise.
For manual mode only. To adjust the minimum-speed potentiometer (Figure
7-8), follow these steps:
1.
Switch the AutoGlue selector switch to the off position.
2.
Turn the glue-flow knob on the hot-melt unit to the full
counterclockwise position.
3.
Adjust the minimum speed potentiometer to the desired motor
speed. (A clockwise rotation will increase the motor speed.)
IR compensation potentiometer
Figure 7-7. IR Compensation Potentiometer
Minimum-Speed
Potentiometer
IR Compensation Potentiometer -
Continued
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...