10-8
Valco Cincinnati, Inc.
Section 10 - Troubleshooting
MC060 Manual/VC350AG AutoGlue Control System
Potentiometer
Setting
Condition
P1
On delay
With SW2-1 in the up position, pot will
adjust valve on delay from 0-17 ms.
P2
Off delay
With SW2-3 in the up position, pot will
adjust valve off delay from 0-17 ms.
P5 Minimum
speed
Clockwise (CW) adjustment – higher
minimum speed before glue enable
Counterclockwise (CCW) adjustment –
lower minimum speed before glue
enable
P6
Dump time
With JP3 in the “old” position, pot will
adjust dump-valve off time after
machine goes below minimum speed
(0 – 10 seconds).
P7 Hot-melt
analog volts
adjustment
When running a hot-melt system,
adjustment will lower 0-10 VDC analog
out to hot-melt speed
Table 10-4. Main Board Potentiometer Adjustments
To ensure that main-board voltage is present, follow these steps:
1.
Turn on the power switch while the parent machine is not
running and ensure that the front-panel power indicator on the
front panel is illuminated (Figure 10-5).
2.
If indicator is not illuminated, insert a red DVM probe into TP5
and a black DVM probe into TP4 on the main board (Figure 10-
4). The meter should read +5V + 0.2V. If it does not read +5V +
0.2V, do the following:
2a.
Ensure that the main panel supply to the control is
on and that the unit is plugged in.
2b.
Ensure that the transformer power-entry cable is
plugged in.
2c.
Check the main power fuse in the power entry
module.
2d.
Check the fuse on the +5/+12V power supply.
2e.
Ensure that both the transformer cable to the power
supply and the power supply cable to the main
board at J10 are properly connected.
Checking the Logic
Voltage
Troubleshooting the Main Board -
Continued
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...