10-7
Valco Cincinnati, Inc.
MC060 Manual/VC350AG AutoGlue Control System
Section 10 - Troubleshooting
Table 10-3. Main Board Switches/Jumpers
Troubleshooting the Main Board -
Continued
Switch/Jumper
Setting
Condition
SW2-1 ON
DS1
On delay potentiometer setting
On delay DS1 setting
SW2-2
SWITCH NOT USED
SW2-3 OFF
DS2
Off delay potentiometer setting
Off delay DS2 setting
1000-line encoder (1.0000 ratio comp setting)
99.99 resolution
250-line encoder (1.0000 ratio for metric)
JP2 STD
ENB-500
250-line encoder (1.9999 ratio comp setting)
999.9 resolution
500-line encoder ( 1.0000 ratio comp setting)
JP1 SC1
SC2
Scanner 2 enables channel 2 (individual-channel mode)
Scanner 1 enables channel 2 (combined-channel mode)
SW13 OLD
DUMP
NEW DUMP
Enables circuit to work with automatic glue-pressure relief valve
Enables circuit to work with pressure relief accumulator
SW12-1 TST/ENC
ENC
Encoder test mode
External encoder mode (normal operation)
SW12-2 TST/SCAN
SCAN
Scanner test mode
External scanner mode (normal operation)
SW12-3 DMP
DMP
Energizes pressure-relief accumulator below minimum speed
Energizes pressure-relief accumulator above minimum speed
SW12-4 CNT1
CNT2
Scanner 1 increments counter (Not used in VC350AG);
Scanner 2 increments counter (only VC350A replacements).
DS1 & DS2
Valve
Compensation
See chart on 7-7. Control will NOT operate if all switches are down
or “off”.
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...