5-3
Valco Cincinnati, Inc.
MC060 Manual/VC350AG AutoGlue Control System
Section 5 - Basic Features
Bottom Panel
Features
Figure 5-2. Bottom-Panel Features
Table 5-2. Description of Bottom-Panel Features
IN
S H O P A IR
R E G . A IR
O U T
E XH A U ST
1
2
3
4
5
6
7
8
9
Item #
Name
Description
1
Flush-mount fluid-flow control
(EPC)
Fluid-flow control manifold block for easy connection and
disconnection of air lines to and from glue pressure system
2
Input port
Port that allows shop air to into control
3
Output port
Port connected to glue-pressure system to boost glue
pressure
4
Exhaust port
Port to exhaust air pressure, which decreases glue
pressure
5
Scanner cable connections
Cable entry point for scanner cables (yellow) with strain
relief
6
Power entry module
Combination power input, main fuse protection block, on/off
switch, and line filter. Input selection for 115V or 230VAC
7
Valve cable connections
Cable entry point for valve cables (blue) with strain relief
8
Encoder cable connection
Cable entry point for encoder cable with strain relief
9
Strain reliefs
For hardware of externally connected devices such as
JP2000, dump valve or pump.
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...