Section 7
—
Initial Setup
VC350A Flexoseal
®
System
Valco Cincinnati
7-10
Minimum-Speed Potentiometer
For manual mode only. To adjust the minimum-speed potentiometer (Figure 7-8), follow these steps:
1. Place selector switch in the manual position.
2. Set the glue-flow knob on the hot-melt unit to the full counterclockwise position.
3. Adjust the minimum speed potentiometer to the desired motor speed. (A clockwise rotation will increase
the motor speed.)
Maximum-Speed Potentiometer
For manual mode only. To adjust the maximum-speed potentiometer (Figure 7-9), follow these steps:
1. Place the selector switch in the manual position.
2. Set the glue flow knob on the hot-melt unit to the full clockwise position.
3. Adjust the maximum speed potentiometer to the desired motor speed. (A clockwise rotation will increase
the motor speed.)
minimum-speed potentiometer
maximum-speed potentiometer
Figure 7-8. Minimum-Speed Potentiometer
Figure 7-9. Maximum-Speed Potentiometer
WARNING! Do not exceed 180VDC armature voltage (circuit board
terminals A1 and A2). OTHERWISE, DEATH, PERSONAL INJURY, OR
EQUIPMENT DAMAGE COULD OCCUR.
Note
!
The minimum speed adjustment will affect the maximum speed setting. Therefore, it is necessary to
readjust the maximum speed after the minimum speed has been adjusted. It may also be necessary to
repeat the operations until both the minimum and maximum speeds are set to the desired levels.
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...