10-6
Valco Cincinnati, Inc.
Section 10 - Troubleshooting
MC060 Manual/VC350AG AutoGlue Control System
Table 10-1. Main Board Test Points
Table 10-2. Main Board LEDs
Troubleshooting the Main Board -
Continued
Test
Points
Signal
Name
Normal
Voltages
Condition
TP6 +12
+12V
Good
power
supply
TP4 GROUND
0V
Good
power
supply
TP5 +5
+5V
Good
power
supply
TP7
ANALOG
0V-10V
V to EPC-6
TP2 RESET 5V
Circuit
running
TP3
MIN SPD
0V-5V
Minimum-speed voltage reference
TP1
ABV MIN
+5V
Parent above minimum speed
LEDs
Status
Condition
D1, D2/ENC
ON
Encoder signal present
D1, D2/ENC
OFF
Machine stopped or no encoder signal present
D3/SCAN ON
(Blinking)
Scanner sensing product
D3/SCAN OFF No
product
D8
ON
Dump valve energized
D8
OFF
Dump valve off
D6/RATIO
ON
Ratio comp working
D6/RATIO
OFF
Ratio comp not working or machine stopped
D4/CTG
Blinking
Counter and circuit working
D5/FLAP
Blinking
Counter and circuit working
D7/GLUE
Blinking
Counter and circuit working
D11/GUN1
Blinking
GUN1 switch on, valve firing
D10/GUN2
Blinking
GUN2 switch on, valve firing (2-channel unit)
D9/MIN
SPEED
ON
Parent machine running above minimum
speed
D9/MIN
SPEED
OFF
Parent machine running below minimum
speed
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...