Section 6
—
Installation
VC350A Flexoseal
®
System
Valco Cincinnati
6-18
Electrical Installation of the DD-1 Pump
There is a connection on the interface board for supplying voltage to the DD-1 pump. The cable used to connect the
pump to the VC350A should have a minimum of two conductors (18-22 AWG).
To connect the pump cable to the control, follow these steps:
1. Insert the pump cable into the control enclosure through a cord grip located on the bottom panel of the
control.
2. Connect the pump cable to the 2-terminal connector labeled “J10-DD-1 PUMP” on the interface board.
Connections are as follows:
Pin 1:
24VAC - Black (new valve cables)
Brown (old valve cables)
Pin 2:
24VAC - White (new valve cables)
Blue (old valve cables)
3. Tighten the cord grip used by the pump cable.
For additional information, see the DD-1 Pump Manual (PN MS005).
Mechanical Installation of the DD-1 Pump
There are two types of DD-1 pump installations:
•
Wall-mounted installation (Figure 6-17)
•
Drum-mounted installation (Figure 6-18)
Figure 6-17. Wall-Mounted Pump
Installation
Figure 6-18. Drum-Mounted Pump Installation
filter
filter
Summary of Contents for VC350A
Page 1: ...VC350A Flexoseal System Manual Number MC037 Release Date May 2001 ...
Page 8: ...Section 1 Introduction VC350A Flexoseal System Valco Cincinnati 1 2 Figure 1 1 VC350A Control ...
Page 68: ...Section 9 Maintenance VC350A Flexoseal System Valco Cincinnati 9 9 Figure 9 4 Fluid Regulator ...
Page 133: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 44 400EZ Glue Valve ...
Page 163: ...Section 12 Part Number List VC350A Flexoseal System Valco Cincinnati 12 74 Fittings ...