5
-34
* 1. The
factory setting depends upon the Inverter capacity. The value for a 200-V class Inverter of 0.4 kW is given.
* 2. The
setting range is 10% to 200% of the Inverter's rated output current. The value for a 200-V class Inverter of 0.4 kW is given.
* 3. The
factory setting depends upon the Inverter capacity. The value for a 200-V class Inverter of 0.4 kW is given.
E2-05
Motor
line-
to-line
resis-
tance
Sets
the motor phase-to-
phase
resistance in
Ω
units.
This
parameter is automati-
cally
set during autotuning.
0.000
to
65.000
9.842
Ω
*1
No
A
A
A
312H
6-127
Term
Resis-
tance
E2-06
Motor
leak
inductance
Sets
the voltage drop due to
motor
leakage inductance as
a
percentage of the motor
rated
voltage.
This
parameter is automati-
cally
set during autotuning.
0.0
to
40.0
18.2%
*1
No
No
No
A
313H
6-127
Leak
Induc-
tance
E2-07
Motor
iron
saturation
coefficient
1
Sets
the motor iron satura-
tion
coefficient at 50% of
magnetic
flux.
This
parameter is automati-
cally
set during autotuning.
0.00
to
0.50
0.50
No
No
No
A
314H
6-127
Saturation
Comp1
E2-08
Motor
iron
saturation
coefficient
2
Sets
the motor iron satura-
tion
coefficient at 75% of
magnetic
flux.
This
parameter is automati-
cally
set during autotuning.
0.00
to
0.75
0.75
No
No
No
A
315H
6-127
Saturation
Comp2
E2-10
Motor
iron
loss
for
torque
com-
pensation
Sets
motor iron loss in W
units.
0
to
65535
14
W
*1
No
A
A
No
317H
6-127
Tcomp
Iron
Loss
E2-11
Motor
rated
output
Set
the rated output of the
motor
in units of 0.01 kW.
This
parameter is automati-
cally
set during autotuning.
0.00
to
650.00
0.40
*1
No
Q
Q
Q
318H
-
Mtr
Rated
Power
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop