Input Terminal Functions
6-
63
K
K
K
K
Blocking
Inverter
Outputs
(Baseblock
Commands)
Set
8 or 9 (Baseblock command NO/NC) in one of the parameters H1-01 to H1-05 (multi-function input ter-
minal
S3 to S7 function selection) to perform baseblock commands using the terminal's ON/OFF operation,
and
prohibit Inverter voltage output using the baseblock commands.
Clear
the baseblock command to restart the operating using speed search from frequency references from the
previous
baseblock command input.
Multi-function
Digital
Inputs
(H1-01
to
H1-05)
n
Time
Chart
The
time chart when using baseblock commands is shown below.
Fig 6.48 Baseblock Commands
Set
Value
Function
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
8
External
baseblock NO (Normally Open contact: Baseblock when ON)
Yes
Yes
Yes
9
External
baseblock NC (Normally Closed contact: Baseblock when OFF)
Yes
Yes
Yes
IMPORTANT
If using baseblock commands with a variable load, do not frequently input baseblock commands during oper-
ation, as this may cause the motor to suddenly start coasting, and may result in the motor falling or slipping.
Forward operation/Stop
Baseblock command
Input
Cleared
Frequency reference
Output frequency
Search from stored frequency reference
Coast to a stop