5
-62
n
Fault
Restart:
L5
Parameters
for restarting faults are shown in the following table.
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
L5-01
Number
of
auto
restart
attempts
Sets
the number of auto
restart
attempts.
Automatically
restarts after a
fault
and conducts a speed
search
from the run fre-
quency.
0
to 10
0
No
A
A
A
49EH
6-59
Num
of
Restarts
L5-02
Auto
restart
operation
selection
Sets
whether a fault contact
output
is activated during
fault
restart.
0: Not
output (Fault contact
is
not activated.)
1: Output
(Fault contact is
activated.)
0
or 1
0
No
A
A
A
49FH
6-59
Restart
Sel