Frequency Reference
6-
7
n
Inputting
the
Frequency
Reference
Using
Voltage
(Analog
Setting)
When
b1-01 is set to 1, you can input the frequency reference from control circuit terminal A1 (voltage input),
or
control circuit terminal A2 (voltage or current input).
Inputting
Master
Speed
Frequency
Reference
Only
(Asian
Model)
If
inputting the master speed frequency reference only, input the voltage reference to control circuit terminal
A1.
Fig 6.4 Master Speed Frequency Reference Input
2-Step
Switching:
Master/Auxiliary
(Asian
Model)
If
performing 2-step switching between master and auxiliary speed frequencies, input the master speed fre-
quency
reference to control circuit terminal A1, and input the auxiliary speed frequency reference to A2.
When
terminal S3 (multi-step speed command 1) is OFF, terminal A1 (master speed frequency reference) will
be
the Inverter frequency reference, and when terminal S3 is ON, terminal A2 (auxiliary speed frequency ref-
erence)
will be the Inverter frequency reference.
Fig 6.5 Master/Auxiliary Frequency Reference Input
Setting
Precautions
When
inputting a voltage signal to terminal A2, observe the following precautions.
•
Turn
OFF pin 2 on DIP switch S1 for switching between voltage and current (factory setting is ON).
Inverter
A1 (Master speed frequency
reference)
+V (Power supply: 15 V,
20 mA)
A2 (Auxiliary speed frequency
reference)
AC (Analog common)
2 k
Ω
(2 W)
(2 W)
0 to 10 V
input
Inverter
+V (Power supply: 15 V,
20 mA)
A1 (Master speed frequency
reference)
0 to 10 V input
DIP switch S1
SC Sequence common
S3 Multi-step speed
command 1
Master/
Auxiliary
A2 (Auxiliary speed frequency
reference)
AC (Analog common)