5
-48
Multi-function
Digital
Output
Functions
H2-03
3G3RV
(Asia)
Terminal
P2
function
select
(con-
tact)
Multi-function
output
2
0
to 37
2
No
A
A
A
40DH
-
Term
P2 Sel
3G3RV
(-E)
(Europe)
Terminal
M5-M6
function
select
(con-
tact)
Term
M5-
M6
Sel
Set-
ting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
loop
Vec-
tor
0
During
run (ON: run command is ON or voltage is being output)
Yes
Yes
Yes
-
1
Zero-speed
Yes
Yes
Yes
-
2
Frequency
agree 1 (L4-02 used.)
Yes
Yes
Yes
-
3
Desired
frequency agree 1 (ON: Output frequency = ±L4-01, L4-02 used and dur-
ing
frequency agree)
Yes
Yes
Yes
-
4
Frequency
(FOUT) detection 1 (ON: +L4-01
≥
output frequency
≥
-L4-01, L4-02
used)
Yes
Yes
Yes
-
5
Frequency
(FOUT) detection 2 (ON: Output frequency
≥
+L4-01 or output fre-
quency
≤
-L4-01, L4-02 used)
Yes
Yes
Yes
-
6
Inverter
operation ready
READY:
After initialization, no faults
Yes
Yes
Yes
-
7
During
DC bus undervoltage (UV) detection
Yes
Yes
Yes
-
8
During
baseblock (ON: during baseblock)
Yes
Yes
Yes
-
9
Frequency
reference selection (ON: Frequency reference from Operator)
Yes
Yes
Yes
-
A
Run
command selection status (ON: Run command from Operator)
Yes
Yes
Yes
-
B
Overtorque/undertorque
detection 1 NO (NO contact: Overtorque/undertorque
detection
at ON)
Yes
Yes
Yes
6-44
C
Loss
of frequency reference (Effective when 1 is set for L4-05)
Yes
Yes
Yes
6-58
D
Braking
resistor fault (ON: Resistor overheat or braking transistor fault)
Yes
Yes
Yes
6-60
E
Fault
(ON: Digital Operator communications error or fault other than CPF00 and
CPF01
has occurred.) (See Table 7.1 for faults.)
Yes
Yes
Yes
-
F
Not
used. (Set when the terminals are not used.)
-
-
-
-
10
Alarm
(ON: Alarm displayed) (See Table 7.2 for alarms.)
Yes
Yes
Yes
-
11
Fault
reset command active
Yes
Yes
Yes
-
12
Timer
function output
Yes
Yes
Yes
6-
116
13
Frequency
agree 2 (L4-04 used)
Yes
Yes
Yes
-
Parameter Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
Summary of Contents for SYSDRIVE 3G3RV
Page 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Page 36: ...1 22...
Page 106: ...3 14...
Page 126: ...4 20...
Page 216: ...5 90...
Page 388: ...7 26...