5
-72
* 1. The
factory setting depends upon the Inverter capacity. The value for a 200-V class Inverter of 0.4 kW is given.
* 2. For
(-E) models.
o2-06
Operation
selection
when
digi-
tal
operator
is
discon-
nected
Sets
the operation when the
Digital
Operator is discon-
nected.
0: Disabled
(Operation
continues
even if the
Digital
Operator is
disconnected.)
1: Enabled
(OPR is detected
at
Digital Operator
disconnection.
Inverter
output
is cut off, and fault
contact
is operated.)
0
or 1
0
No
A
A
A
50AH
-
Oper
Detec-
tion
o2-07
Cumulative
operation
time
setting
Sets
the cumulative opera-
tion
time in hour units.
Operation
time is calculated
from
the set values.
0
to
65535
0
hr
No
A
A
A
50BH
6-135
Elapsed
Time
Set
o2-08
Cumulative
operation
time
selec-
tion
0: Cumulative
time when
the
Inverter power is on.
(All
time while the
Inverter
power is on is
accumulated.)
1: Cumulative
Inverter run
time.
(Only Inverter
output
time is
accumulated.)
0
or 1
0
(1)
*2
No
A
A
A
50CH
-
Elapsed
Time
Run
o2-09
Factory
use
Do
not change.
-
-
No
A
A
A
-
-
Init
Mode
Sel
o2-10
Fan
opera-
tion
time
setting
Set
the initial value of the
fan
operation time using
time
units.
The
operation time accumu-
lates
from the set value.
0
to
65535
0
hr
No
A
A
A
50EH
6-135
Fan
ON
Time
Set
o2-12
Fault
trace/
fault
his-
tory
initial-
ization
0: Disable
(U2, U3 are held)
1:
Enable (U2, U3 are ini-
tialized
and o2-12 returns
to
0.) For (-E) models
only.
0
or 1
0
No
A
*2
A
*2
A
*2
510H
-
FLT
Trace
Init
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Register Page
LCD
Display
V/f
V/f
with
PG
Open
Loop
Summary of Contents for SYSDRIVE 3G3RV
Page 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Page 36: ...1 22...
Page 106: ...3 14...
Page 126: ...4 20...
Page 216: ...5 90...
Page 388: ...7 26...