Monitor Parameters
6-
73
* 1. For
(-E) models. The shunt connector CN15 must be set. For details, refer to page 2-43.
* 2. Analog
Monitor Cards are not available for (-E) models. Use the AM or FM terminal as a substitute.
n
Selecting
Analog
Monitor
Items
The
digital operator monitor items (U1-
oo
[status monitor]) are output from multi-function analog output
terminals
FM-AC and AM-AC. Refer to Chapter 5 Parameters, and set the values for the
oo
part of U1-
oo
(status
monitor).
Alternatively,
you can output monitor items (U1-
oo
[status monitor]) from analog output option terminal
channels
1 and 2 on analog monitor cards AO-08 and AO-12. Refer to the table of parameters, and set the val-
ues.
n
Adjusting
the
Analog
Monitor
Items
Adjust
the output voltage for multi-function analog output terminals FM-AC and AM-AC using the gain and
bias
in H4-02, H4-03, H4-05, and H4-06. Also, adjust the output voltage for output channels 1 and 2 of Ana-
log
Output Option Cards AO-08 and AO-12 using the gain and bias in F4-02, F4-04, and F4-06.
Adjusting
the
Meter
Display
the data setting display for the gain and bias constants corresponding to the output channel of the
Inverter
Unit and the AO Option Card while the Inverter is stopped to output the following voltages to the ana-
log
monitor terminal, to enable meter adjusting while the Inverter is stopped.
F4-01
Channel
1 monitor selec-
tion
Effective
when the Analog Monitor Card is used.
Monitor
selection:
Set
the number of the monitor item to be output.
(U1-
oo
)
Gain:
Set
the multiple of 10 V for outputting monitor
items.
4,
10 to 14, 28, 34, 39, 40 cannot be set. 17, 23, 25,
29,
30, 31, 35 are not used.
When
the AO-12 Analog Monitor Card is used,
outputs
of ±10 V are possible. To output ±10 V, set
F4-07
or F4-08 to 1. When the AO-08 Analog
Monior
Card is used, only outputs of 0 to +10 V
are
possible.
A
meter calibration function is available.
1
to 40
2
No
A
*2
A
*2
A
*2
AO
Ch1 Select
F4-02
Channel
1 gain
0.00
to
2.50
1.00
Yes
A
*2
A
*2
A
*2
AO
Ch1 Gain
F4-03
Channel
2 monitor selec-
tion
1 to 40
3
No
A
*2
A
*2
A
*2
AO
Ch2 Select
F4-04
Channel
2 gain
0.00
to
2.50
0.50
Yes
A
*2
A
*2
A
*2
AO
Ch2 Gain
F4-05
Channel
1 output monitor
bias
Set
the channel 1 item bias to 100%/10 V when
the
analog monitor card is used.
-10.0
to
10.0
0.0
Yes
A
*2
A
*2
A
*2
AO
Ch1 Bias
F4-06
Channel
2 output monitor
bias
Set
the channel 2 item bias to 100%/10 V when
the
analog monitor card is used.
-10.0
to
10.0
0.0
Yes
A
*2
A
*2
A
*2
AO
Ch2 Bias
F4-08
Analog
output signal level
for
channel 2
0:
0 to 10 V
1:
-10 to 10 V
0
or 1
0
No
A
*2
A
*2
A
*2
AO
Opt Level Ch1
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
Summary of Contents for SYSDRIVE 3G3RV
Page 1: ...USER S MANUAL SYSDRIVE 3G3RV High function General purpose Inverters Cat No I532 E1 1...
Page 36: ...1 22...
Page 106: ...3 14...
Page 126: ...4 20...
Page 216: ...5 90...