2
-42
* 1. The
default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-step speed setting 1
for
S6 and multi-step speed setting 2 for S7.
* 2. When
driving a reactive load, such as a relay coil, always insert a flywheel diode as shown in Fig 2.31.
* 3. Pulse
input specifications are given in the following table.
Fig 2.31 Flywheel Diode Connection
Analog
output
signals
FM
Multi-function
analog output
(frequency
output)
0
to +10 V/100% fre-
quency
Multi-function
analog
monitor 1
0
to +10 V max. ±5%
2
mA max.
AC
Analog
common (copy)
-
AM
Multi-function
analog output
(current
monitor)
5
V/Inverter's rated cur-
rent
Multi-function
analog
monitor 2
Pulse
I/O
RP
Pulse
input
*3
H6-01
(Frequency reference input)
0
to 32 kHz (3 k
Ω
)
High
level voltage 3.5 to
13.2
V
MP
Pulse
monitor
H6-06
(Output frequency)
0
to 32 kHz
+5
V output
(Load: 1.5 k
Ω
)
RS-
485/
422A
R+
RS-422A/485
communica-
tions
input
For
2-wire RS-485, short R+ and S+ as well
as
R- and S-.
Differential
input,
photocoupler
isolation
R-
S+
RS-422A/485
communica-
tions
output
Differential
input,
photocoupler
isolation
S-
IG
Signal
common
-
-
Low
level voltage
0.0
to 0.8 V
High
level voltage
3.5
to 13.2 V
H
duty
30%
to 70%
Pulse
frequency
0
to 32 kHz
Table 2.21 Control Circuit Terminals (Continued)
Type
No.
Signal
Name
Function
Signal
Level
External power:
48 V max.
Coil
Flywheel diode
50 mA max.
The rating of the flywheel diode
must be at least as high as the
circuit voltage.