Options
6-
143
Options
This
section explains the Inverter option functions.
K
K
K
K
Performing
Speed
Control
with
PG
This
section explains functions with V/f control with PG.
n
Related
Parameters
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control
Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
LCD
Display
F1-01
PG
constant
Set
the number of PG (pulse generator or encoder)
pulses.
Sets the number of pulses per motor revo-
lution.
0
to
60000
600
(1024)*
No
No
Q
No
PG
Pulsed/Rev
F1-02
Operation
selection at PG
open
circuit (PGO)
Sets
the PG disconnection stopping method.
0:
Ramp to stop (Deceleration stop using the
deceleration
time 1, C1-02.)
1:
Coast to stop
2:
Fast stop (Emergency stop using the decelera-
tion
time in C1-09.)
3:
Continue operation (To protect the motor or
machinery,
do not make this setting.)
0
to 3
1
No
No
A
No
PG
Fdbk Loss Sel
F1-03
Operation
selection at
overspeed
(OS)
Sets
the stopping method when an overspeed (OS)
fault
occurs.
0:
Ramp to stop (Deceleration stop using the
deceleration
time 1, C1-02.)
1:
Coast to stop
2:
Fast stop (Emergency stop using the decelera-
tion
time in C1-09.)
3:
Continue operation (To protect the motor or
machinery,
do not make this setting.)
0
to 3
1
No
No
A
No
PG
Overspeed Sel
F1-04
Operation
selection at
deviation
(DEV)
Sets
the stopping method when a speed deviation
(DEV)
fault occurs.
0:
Decelerate to stop (Deceleration stop using the
deceleration
time 1, C1-02.)
1:
Coast to stop
2:
Emergency stop (Emergency stop using the
deceleration
time in C1-09.)
3:
Continue operation (DEV is displayed and
operation
continued.)
0
to 3
3
No
No
A
No
PG
Deviation Sel
F1-05
PG
rotation
0:
Phase A leads with forward run command.
(Phase
B leads with reverse run command.)
1:
Phase B leads with forward run command.
(Phase
A leads with reverse run command.)
0
or 1
0
No
No
A
No
PG
Rotation Sel
F1-06
PG
division rate (PG pulse
monitor)
Sets
the division ratio for the PG speed control
card
pulse output.
Division
ratio = (1 + n)/m
(n
= 0 or 1, m = 1 to 32)
This
parameter is effective only when a PG-B2 is
used.
The
possible division ratio settings are 1/32
≤
F1-
06
≤
1
1
to 132
1
No
No
A
No
PG
Output Ratio
F1-07
Integral
value during accel/
decel
enable/disable
Sets
integral control during acceleration/decelera-
tion
to either enabled or disabled.
0:
Disabled (The integral function isn't used
while
accelerating or decelerating; it is used at
constant
speeds.)
1:
Enabled (The integral function is used at all
times.)
0
or 1
0
No
No
A
No
PG
Ramp PI/I Sel
F1-06
n
m